MeyerFire
  • Blog
  • Forum
  • THE TOOLKIT
    • SUBMIT AN IDEA
    • BACKFLOW DATABASE*
    • CLEAN AGENT ESTIMATOR*
    • CLOUD CEILING CALCULATOR
    • DOMESTIC DEMAND*
    • FIRE FLOW CALCULATOR*
    • FIRE PUMP ANALYZER*
    • FIRE PUMP DATABASE*
    • FRICTION LOSS CALCULATOR
    • HANGER SPACER*
    • IBC TRANSLATOR*
    • K-FACTOR SELECTOR*
    • NFPA 13 EDITION TRANSLATOR ('19 ONLY)
    • NFPA 13 EDITION TRANSLATOR ('99-'22)*
    • LIQUIDS ANALYZER*
    • OBSTRUCTION CALCULATOR
    • OBSTRUCTIONS AGAINST WALL*
    • PLUMBING FIXTURE COUNTS
    • QUICK RESPONSE AREA REDUCTION
    • REMOTE AREA ANALYZER*
    • SPRINKLER DATABASE*
    • SPRINKLER FLOW*
    • SYSTEM ESTIMATOR*
    • TEST & DRAIN CALCULATOR
    • THRUST BLOCK CALCULATOR
    • TRAPEZE CALCULATOR
    • UNIT CONVERTER
    • VOLUME & COMPRESSOR CALCULATOR
    • WATER STORAGE*
    • WATER SUPPLY (US)
    • WATER SUPPLY (METRIC)
  • UNIVERSITY
    • About
    • Catalog
    • CONTENT LIBRARY
  • PE Exam
    • PE Forum & Errata
    • PE Store
    • PE Tools
    • PE Prep Series
    • PE 100-Day Marathon
  • LOGIN
  • PRICING
    • SOFTWARE & TRAINING
    • STORE
  • THE CAUSE
    • ABOUT US
    • BECOME AN INSTRUCTOR
    • HELP/SUPPORT
Picture

When is Auto Ball Drip Needed for FDC?

1/31/2020

3 Comments

 
When is the auto ball-drip required on the hookup (dry) side of the check valve for a Fire Department Connection?

In areas prone to freezing, there is the FDC, then a dry portion of pipe, then the check valve. If the check valve is located higher than the FDC (as is typical for our FDCs near risers), can't the connection itself drain the dry portion?

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
3 Comments

Panic Hardware for Industrial Occupancy Exit?

1/30/2020

2 Comments

 
Are exits in industrial occupancies required to have panic hardware if the overall number of employees is 50 or more?

This is under NFPA 101 Life Safety Code, 2018 edition. Thanks.

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
2 Comments

Code Requirements Surrounding Traffic Spikes?

1/29/2020

1 Comment

 
Does anyone have any code references for the use of traffic spikes?

Does anyone allow it (with a manual override)?

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
1 Comment

Measure Egress Diagonally Across Open Room?

1/28/2020

16 Comments

 
I'm working on an exercise studio with one big open room and dealing with a plan examiner who insists travel distance is measured along walls leading to an exit, rather than diagonally across the space. To me this is absurd. Thoughts?

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
16 Comments

Sprinklers Required Below Group of Pipes?

1/27/2020

9 Comments

 
I have an obstruction question regarding what I feel is a gray area of NFPA 13. I'm looking at obstructions greater than 18 inches below sprinklers.

NFPA 13 states that any obstruction over 4 ft wide requires sprinkler protection under the obstruction. What if you have multiple parallel obstructions that are less than 4 ft wide with gaps in between?

For example, multiple 36-inch diameter parallel pipes with 6 inches of space between each pipe.

I feel that even if these obstructions do not require sprinkler protection below per code, they would still significantly alter the listed spray pattern of the sprinkler. I have seen some info regarding a 50% rule, but I can only find that in code as it relates to ceiling fans.

I am curious what other opinions are. Thanks!

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
9 Comments

Sprinklers in Attic for Gas-Fired Mech. Equipment?

1/24/2020

4 Comments

 
Working on a fire house that is fully-sprinklered, non-separated construction type V-B, wood construction, R-2, S-1 & S-2 classifications, with R-2 being the most restrictive. We have 83 total occupants. IBC 2015.

We have a full- sprinklered attic with a nitrogen generator. We have gas-fired mechanical equipment in the attic.

My question is that the contractor is suggesting to VE the attic sprinkler by installing fire treated roof sheathing. IBC 903.2.8.3.2 "Attics not used for living purposes, storage or fuel-fired equipment." tells me that we are required to have them. Am I incorrect?

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
4 Comments

Elevator Relay Location With No Machine Room?

1/23/2020

5 Comments

 
When an elevator does not have an elevator machine room, where should the fire alarm relays for the elevator be located?

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
5 Comments

Requirements for Cane-Detection at Standpipes?

1/22/2020

5 Comments

 
Within stairwells, how are standpipes addressed in regards to cane detection with ABA/ADA rules? Are there any special cane-detection requirements (anything special to allow a visually-impaired person to detect a vertical standpipe)?

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
5 Comments

Is Pipe An Obstruction to In-Rack Sprinklers?

1/21/2020

5 Comments

 
Does anyone have any literature on the installation of face sprinklers (the sprinkler along the first row of a rack on the "face" of the rack)?

I have an AHJ who is saying that the height of the pipes serving the face sprinklers must not meet the definition of "hindrance" or "obstruction" in the building code. 

The face sprinklers in my situation are placed on first row of a rack system with the face sprinklers of the upright type. (2015 NFPA-30 16.5.1.10 (6)).  The sprinkler line is located parallel with the face of the rack. The bottom of the pipe is 4"-6" below the bottom of the rack. 

I have checked for the definition of what he mentioned and I can't find anything in the building codes. Building code is 2015 IBC/IFC.  Also checked the NFPA-13 handbooks but the installation requirements are concerned with sprinkler deflector versus the piping itself.  Thanks in advance!

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
5 Comments

Underground Gate Valves Need Monitoring?

1/20/2020

4 Comments

 
Do underground gate valves for fire main water supplies have to be monitored and supervised?

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
4 Comments

Announcing The Top Overall Contributors of 2019

1/17/2020

2 Comments

 
As you might have heard by now this site is all about promoting fire protection by sharing best practices and bringing together a community of experts from different backgrounds. As part of that goal I'm happy to announce the overall Top Ten Contributors to the Daily Forum for 2019:
Picture
Dan Wilder
Dave L.
Franck Orset
James
Mike

Pete
Rusty Scott
Sean
Wayne Ammons
​Wes

On behalf of MeyerFire & all of us on the forum, thank you for your valued and regular input on the forum! The great conversations here do nothing but all of us in the industry learn and grow.

Top Contributors for 2019 each have been sent a plaque (like the one shown above) as a small token of appreciation.
2 Comments

Exact Source Point for Hydraulic Calculations?

1/17/2020

9 Comments

 
Where exactly does a hydraulic calculation need to end? 

When we run a hydrant flow test, there's a static/residual hydrant and a flow hydrant. I regularly run my hydraulic calculations from the building, through the service main, to a street main, and then up the tee'd branch that serves a hydrant so that my source point is exactly at the elevation of the static/residual hydrant. I do this so that I make sure to account for the proper elevation of the water supply.

Most other hydraulic calculations I see will end wherever the building's service main intersects with the street's supply. Is this correct? Wouldn't that place the source at an elevation lower than what the hydrant indicated is available?

Wondering what the proper way is that I should be precisely calculating systems. Thanks in advance.

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
9 Comments

Ordinary Hazard within Light Hazard "Building"?

1/16/2020

10 Comments

 
What should I do about a sprinkler contractor who insists that rooms of dedicated Ordinary Hazard occupancy (storage, janitors, mechanical etc.) within an otherwise Light Hazard occupancy building can be protected as Light Hazard?

NFPA 13 clearly provides direction for adjacent and multiple hazard classifications. I think Chapter 5 and 11 (and common sense) are clear on this. Classroom Labs are even another matter that NFPA has addressed. Do you all run into this "it's all light hazard" belief as well?

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
10 Comments

Min. Distance to Heat Ducts & Steam at Ceilings?

1/15/2020

2 Comments

 
When sprinklers (recessed, pendant, or concealed) are installed in a ceiling, do the distances to heating ducts and steam piping listed in Table 8.3.2.5(a) of NFPA 13-13 still apply when those elements are above a ceiling?

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
2 Comments

Floor Control Valves on Each Stair in Highrises?

1/14/2020

11 Comments

 
I have a question that a architect brought up to me.  He is saying that on a highrise (11 stories) it is a fire code requirement to have floor control valves on both stairwells. I cannot find anything that states this in any of the NFPA books. The square foot of each floor is small and is NOT separated into zones.

Does an 11-story high-rise require floor control valves on both stairwells?

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
11 Comments

Building Area Increase Permitted for NFPA 13R?

1/13/2020

9 Comments

 
Will you please clarify why a Building Area Increase is NOT permitted for an NFPA 13R design?

We are working on a project and the architect has stated that the calculations following IBC T506.2 allow for an area increase up to 135,000 sf. We are working in IBC 2015. The Owner would like confirmation that the 4 story R-2 Type V-A building can be protected under NFPA 13R when it is over 12,000 sf.

​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
9 Comments

Is Duct Within 18" of Sprinkler an Obstruction?

1/10/2020

4 Comments

 
I could use some help with sprinkler obstructions.

Generally, I’m looking at piping and ductwork, that is installed within 18” below the plane of the standard upright sprinkler deflector. Light or ordinary occupancies.

I called NFPA 13 and got an interpretation that these would be considered a sprinkler obstruction, and I would need sprinklers on either side, regardless of the size of the duct/pipe (no rule here about only being over 4’). This was per Section 10.2.7.2 in the 2019 edition.

I didn’t think to ask, but could I still apply the three times rule of 10.2.7.2.1.3, even though these aren’t structural members? As long as I was three times, or 24-inches away, it wouldn’t be an obstruction, right?

I’ve seen these close configurations all over the place in many different peoples’ designs, so I’m wondering if I’m missing some allowance.

Most recently, I observed a 14” wide (horizontally) x 6” deep duct (vertically), with a sprinkler installed directly above with the deflector 5” above the top of the duct. The next sprinkler head is approximately 12 feet away. Also observed in the same room, was a 5” diameter pipe about 8” diagonally down from a deflector, measured at a 45-degree angle. If I’m understanding NFPA 13 correctly, these would both be considered obstructed. I have a question into NFPA 13, but would appreciate others’ opinions as well.

​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
4 Comments

Backup Power for Diesel Exhaust, Heat, Jockey?

1/9/2020

6 Comments

 
NFPA 20, 4.12.6 "Ventilation. Provision shall be made for ventilation of a pump room or pump house."

DIESEL FIRE PUMPS - These rooms require a lot more air for combustion air and heat removal. This is usually done in generator and boiler rooms with separate fan-forced intake air and exhaust ducts to the outside. In the case of a fire pump, fireproofing these ducts through the building offer additional "protection" under NFPA 20, 4.12.1 in the event of a fire. Diesel data sheets show the amount of CFM required for the various engines. In addition, the extra distance for the exhaust pipe lengths to the outside needs to be considered. Some of the engine manufacturers have calculators on their websites for VENTILATION, COOLING LOOP and EXHAUST PIPING.

PUMP ROOM TEMPERATURE LIMITS - Most microprocessor controllers are limited to 120 deg. F. A small non-vented pump room, especially on a west wall, could easily exceed that with a motor running under load on a hot 100+ degree day.

My question? This site/facility does not have an emergency backup generator. Do we need a backup generator to power the exhaust fan and/or the unit heater?

In the event of power loss during winter… a room temp sensor would send supervisory alarm company for an owner response.

Also, please confirm the Jockey pump does not require backup power.

​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
6 Comments

Use Quick Response Sprinklers in Dry System?

1/8/2020

4 Comments

 
I would appreciate some feedback on using quick response sprinklers in a dry system. I have found no reference in NFPA 13 indicating specifically if QR Uprights can or can not be used.  Therefore, I assume that they are acceptable providing it is a light or ordinary hazard classification. 

I have researched and found varying opinions.  I believe fire testing shows that the use of QR sprinklers in dry systems can help decrease fluid delivery time.  However, with more sprinklers operating before the water arrives to control the fire, some argue that there is increased system demand.  I agree with both scenarios, however, I don't believe the amount of sprinklers operating would exceed the design area of a properly calculated system. 

I would love to hear some different opinions on the subject.

Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
4 Comments

Is a Thrust Block Required on a Straight Coupling?

1/7/2020

2 Comments

 
For straight pipe couplings, are thrust blocks required, or is it only at any change of direction in the piping? It seems as though restrained joints seem to be common now, but the question came up when using thrust blocks instead of the restrained joints.

Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
2 Comments

Factors You Consider for Selecting A Dry-Valve?

1/6/2020

3 Comments

 
I occasionally am the one to choose which dry valve make and model we use for our installation projects. If you're a specifying engineer/designer or on the contractor side of things, what criteria do you consider when you choose when deciding which dry valve model to use?

Obviously the calculations have to accomodate the pressure loss, but that mostly impacts size. What other factors do you consider when making the decision?

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
3 Comments

What Tool Would You Like to See Developed?

1/6/2020

 
A non-anonymous post from Joe: 

What one tool would you like to see developed that would positively impact your line of work? 

Perhaps it's an improvement on an existing tool, an entirely new tool over a topic you struggle with, a hand calculation that you do repeatedly, or a spreadsheet that you've started to develop.

What concepts can I help support for you in 2020? Shoot me an email at joe@meyerfire.com.

What Jurisdictions Require Full-Design w/ Permit?

1/3/2020

8 Comments

 
As an engineering consultant I've worked across a good scattering of the continental US. Occasionally I find jurisdictions who do not allow a "performance-specification" set of documents, but rather require that the fire sprinkler system be entirely laid out and hydraulically calculated with the building permit submittal.

Right now I'm aware of some areas in Florida and New York City as being two that have stood out as having this requirement.

In your experience is this common? What other jurisdictions do you know of require "full-design"?

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
8 Comments

Thanks to Top December 2019 Contributors!

1/3/2020

 
Thank you to all forum contributors for December. We're continually seeing an uptick in interest and expertise (over 100% more input since last December), and I appreciate your willingness to encourage growth in our industry with your contributions! Here's the top commenters for December 2019:
1. Mike
2. Sean
3. James
​4. Mike L.
5. Wayne A.
6. Marc V.
​7. Colin L.
8. Alfrid
9. Vinnie
​10. Marina A.

How is Safety Factor Applied for Clean Agent?

1/2/2020

1 Comment

 
NFPA 2001 requires a safety factor under sections 5.4.2.3 through 5.4.2.5 for clean agent extinguishing concentrations.

What is the difference between the "design concentration" listed in Table A.5.4.2.2(b) (2015 edition) and this minimum extinguishing concentration (the minimum extinguishing concentration MEC x applied safety factor)?

In some cases the design concentrations are higher than the MEC x safety factor - is there a proper one to be using under NFPA 2001? Sorry if the question is basic - I've always just used the design concentrations.

​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
1 Comment
    Picture
    Why Sponsor?

    ALL-ACCESS

    Picture
    GET ALL OUR TOOLS

    SUBSCRIBE

    Subscribe and learn something new each day:
    I'm Interested In:

    COMMUNITY

    Top ​2022 Contributors
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    SEE LEADERBOARD

    YOUR POST

    SUBMIT A QUESTION

    PE EXAM

    Get 100 Days of Free Sample Questions right to you!
    SIGN ME UP!

    FILTERS

    All
    A117.1
    ABA
    ADA
    ASCE 7
    ASME A17.1
    ASTM E1354
    Daily Discussion
    Design Documents
    EN 12845
    Explosion Protection & Prevention
    Fire Detection And Alarm Systems
    Fire Dynamics
    Flammable & Combustible LIquids
    FM Global
    Human Behavior
    IBC
    ICC-500
    IFC
    IMC
    IPC
    IRC
    ISO
    Means Of Egress
    NBC
    NFPA 1
    NFPA 10
    NFPA 101
    NFPA 11
    NFPA 110
    NFPA 1142
    NFPA 1221
    NFPA 13
    NFPA 13D
    NFPA 13R
    NFPA 14
    NFPA 15
    NFPA 16
    NFPA 17A
    NFPA 20
    NFPA 2001
    NFPA 214
    NFPA 22
    NFPA 220
    NFPA 24
    NFPA 241
    NFPA 25
    NFPA 291
    NFPA 30
    NFPA 33
    NFPA 400
    NFPA 409
    NFPA 415
    NFPA 495
    NFPA 497
    NFPA 5000
    NFPA 502
    NFPA 54
    NFPA 55
    NFPA 654
    NFPA 68
    NFPA 70
    NFPA 701
    NFPA 72
    NFPA 75
    NFPA 82
    NFPA 855
    NFPA 90A
    NFPA 92
    NFPA 96
    NICET
    OBC
    Passive Building Systems
    PE Prep Guide
    PE Prep Series
    PE Sample Problems
    Poll
    Smoke Management
    Special Hazard Systems
    UFC 3 600 01
    UFC 3-600-01
    UFC 4-021-01
    Updates
    Water Based Fire Suppression
    Weekly Exams


    ARCHIVES

    January 2023
    December 2022
    November 2022
    October 2022
    September 2022
    August 2022
    July 2022
    June 2022
    May 2022
    April 2022
    March 2022
    February 2022
    January 2022
    December 2021
    November 2021
    October 2021
    September 2021
    August 2021
    July 2021
    June 2021
    May 2021
    April 2021
    March 2021
    February 2021
    January 2021
    December 2020
    November 2020
    October 2020
    September 2020
    August 2020
    July 2020
    June 2020
    May 2020
    April 2020
    March 2020
    February 2020
    January 2020
    December 2019
    November 2019
    October 2019
    September 2019
    August 2019
    July 2019
    June 2019
    May 2019
    April 2019
    March 2019
    February 2019
    January 2019
    December 2018
    November 2018
    October 2018
    September 2018
    August 2018
    July 2018
    June 2018
    May 2018
    November 2017
    October 2017
    September 2017
    August 2017
    July 2017
    June 2017
    November 2016
    October 2016
    July 2016
    June 2016


    PE PREP SERIES

    Fire Protection PE Exam Prep
    SEE LEADERBOARD

    RSS Feed

Picture
​Home
Our Cause
The Blog
The Forum
PE Exam Prep
The Toolkit

MeyerFire University
​Pricing
Login
​Support
Contact Us
Picture

MeyerFire.com is a startup community built to help fire protection professionals shine.
Our goal is to improve fire protection practices worldwide. We promote the industry by creating helpful tools and resources, and by bringing together industry professionals to share their expertise.

​MeyerFire, LLC is an International Code Council Preferred Education Provider.

All text, images, and media ​Copyright © 2022 MeyerFire, LLC

We respect your privacy and personal data. See our Privacy Policy and Terms of Service. 
The views, opinions, and information found on this site represent solely the author and do not represent the opinions of any other party, nor does the presented material assume responsibility for its use. Fire protection and life safety systems constitute a critical component for public health and safety and you should consult with a licensed professional for proper design and code adherence.

Discussions are solely for the purpose of peer review and the exchange of ideas. All comments are reviewed. Comments which do not contribute, are not relevant, are spam, or are disrespectful in nature may be removed. Information presented and opinions expressed should not be relied upon as a replacement for consulting services. Some (not all) outbound links on this website, such as Amazon links, are affiliate-based where we receive a small commission for orders placed elsewhere.

  • Blog
  • Forum
  • THE TOOLKIT
    • SUBMIT AN IDEA
    • BACKFLOW DATABASE*
    • CLEAN AGENT ESTIMATOR*
    • CLOUD CEILING CALCULATOR
    • DOMESTIC DEMAND*
    • FIRE FLOW CALCULATOR*
    • FIRE PUMP ANALYZER*
    • FIRE PUMP DATABASE*
    • FRICTION LOSS CALCULATOR
    • HANGER SPACER*
    • IBC TRANSLATOR*
    • K-FACTOR SELECTOR*
    • NFPA 13 EDITION TRANSLATOR ('19 ONLY)
    • NFPA 13 EDITION TRANSLATOR ('99-'22)*
    • LIQUIDS ANALYZER*
    • OBSTRUCTION CALCULATOR
    • OBSTRUCTIONS AGAINST WALL*
    • PLUMBING FIXTURE COUNTS
    • QUICK RESPONSE AREA REDUCTION
    • REMOTE AREA ANALYZER*
    • SPRINKLER DATABASE*
    • SPRINKLER FLOW*
    • SYSTEM ESTIMATOR*
    • TEST & DRAIN CALCULATOR
    • THRUST BLOCK CALCULATOR
    • TRAPEZE CALCULATOR
    • UNIT CONVERTER
    • VOLUME & COMPRESSOR CALCULATOR
    • WATER STORAGE*
    • WATER SUPPLY (US)
    • WATER SUPPLY (METRIC)
  • UNIVERSITY
    • About
    • Catalog
    • CONTENT LIBRARY
  • PE Exam
    • PE Forum & Errata
    • PE Store
    • PE Tools
    • PE Prep Series
    • PE 100-Day Marathon
  • LOGIN
  • PRICING
    • SOFTWARE & TRAINING
    • STORE
  • THE CAUSE
    • ABOUT US
    • BECOME AN INSTRUCTOR
    • HELP/SUPPORT