MeyerFire
  • Blog
  • Forum
  • THE TOOLKIT
    • SUBMIT AN IDEA
    • BACKFLOW DATABASE*
    • CLEAN AGENT ESTIMATOR*
    • CLOUD CEILING CALCULATOR
    • DOMESTIC DEMAND*
    • FIRE FLOW CALCULATOR*
    • FIRE PUMP ANALYZER*
    • FIRE PUMP DATABASE*
    • FRICTION LOSS CALCULATOR
    • HANGER SPACER*
    • IBC TRANSLATOR*
    • K-FACTOR SELECTOR*
    • NFPA 13 EDITION TRANSLATOR ('19 ONLY)
    • NFPA 13 EDITION TRANSLATOR ('99-'22)*
    • LIQUIDS ANALYZER*
    • OBSTRUCTION CALCULATOR
    • OBSTRUCTIONS AGAINST WALL*
    • PLUMBING FIXTURE COUNTS
    • QUICK RESPONSE AREA REDUCTION
    • REMOTE AREA ANALYZER*
    • SPRINKLER DATABASE*
    • SPRINKLER FLOW*
    • SYSTEM ESTIMATOR*
    • TEST & DRAIN CALCULATOR
    • THRUST BLOCK CALCULATOR
    • TRAPEZE CALCULATOR
    • UNIT CONVERTER
    • VOLUME & COMPRESSOR CALCULATOR
    • WATER STORAGE*
    • WATER SUPPLY (US)
    • WATER SUPPLY (METRIC)
  • UNIVERSITY
    • About
    • Catalog
    • CONTENT LIBRARY
  • PE Exam
    • PE Forum & Errata
    • PE Store
    • PE Tools
    • PE Prep Series
    • PE 100-Day Marathon
  • LOGIN
  • PRICING
    • SOFTWARE & TRAINING
    • STORE
  • THE CAUSE
    • ABOUT US
    • BECOME AN INSTRUCTOR
    • HELP/SUPPORT
Picture

Poll: How Much Pre-Bid & At-Risk Design?

3/31/2020

 
Submitted: I recently came across a project that was out for bid and in the engineer's specifications required all bidding submitters to provide complete plans and hydraulic calculations to be submitted with their bid. I almost laughed out loud.

This wasn't a basic project (senior care roughly 130,000 sqft), but also not a project with some sort of critical design needs either. I would be curious to have a poll, specifically for contractors and their design teams, that asks about how much effort (square footage / layout sprinklers / layout sprinklers and pipe / calc & size pipe / complete material lists) they typically put into an estimate when they only get "performance-specification" or "design-build" specifications.

I don't know if some engineers know (or care) how much effort goes into bidding, but I'd be interested to see what the industry as a whole does. Of course when bidding, all that time is at-risk of being completely wasted without winning the bid.
SEE THE POLL

​​​​​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe

Best Sprinkler Design for Open Breezeways?

3/30/2020

4 Comments

 
In your opinion, what's the best way to address sprinkler design when there are open breezeways separating units in the same building?

Do you somehow provide a heated chase under a deck? Convert from CPVC to steel and heat-trace a run? Go back underground and potentially "under" the building? Use separate risers for each grouping, bumping up the price significantly?

Residential multi-unit apartment complexes are frequently built with open breezeways in-between blocks of units. These usually have paved concrete at the bottom, only wood joists and decking for stairways and walking areas, and a covered roof at the top. 

​​​​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe​
4 Comments

Does FM Global Recognize QR-Area Reduction?

3/27/2020

8 Comments

 
NFPA 13 has the hydraulic remote area reduction for use of Quick-Response sprinklers for wet, light/ordinary hazard, low(er) ceilings without pockets.

Does FM Global recognize anything similar for the use of quick-response sprinklers, or is their HC-1, HC-2, and HC-3 categorization the minimum remote area size regardless of sprinkler RTI? 

​I've checked FM Global Data Sheet 2-0 and 3-26, but have yet to find anything similar in nature.

​​​​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe​
8 Comments

How is "Passenger-Handling Area" defined?

3/26/2020

3 Comments

 
Per NFPA 415 (Section 4.5.1.3) “Passenger-handling areas shall be classified as Ordinary Hazard Group 1 Occupancy, as defined in NFPA 13, for the purpose of sprinkler system design.”   

Is there a guideline to what areas in an airport are “Passenger-handling areas”? There isn't a formal definition in NFPA 415.

​​​​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe​
3 Comments

Any Limits on Fire Service Entry Due to Seismic?

3/25/2020

1 Comment

 
I have a project that is Seismic Design Category D. I'm researching and I thought there were requirements that stemmed from the Northridge Earthquake in 1994 related to the limiting the height/length of the sprinkler service entry.

Is there a 5-foot limit from the underground to the riser for seismic projects?

​​​​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe​
1 Comment

Fiberglass Reinforced Polymer Non-Combustible?

3/24/2020

2 Comments

 
Could Fiberglass Reinforced Polymer materials be considered non-combustible? For this project it's intended to be used as an interior building material.

NFPA 130 & NFPA 101 definition of non-combustible material:

4.7  Non-combustible material
A material that complies with any of the following shall be considered a noncombustible material [101:4.6.13.1].
  1. A material that, in the form in which it is used and under the conditions anticipated, will not ignite, burn, support combustion, or release flammable vapors, when subjected to fire or heat. [101:4.6.13.1(1)]
  2. A material that is reported as passing ASTM E136. [101:4.6.13.1)2)]
  3. A material that is reported as complying with the pass/fail criteria of ASTM E136 when tested in accordance with the test method and procedure in ASTM E2652.  [101:4.6.13.1(3)]

Fiberglass Reinforced Polymer (FRP) materials can meet the following minimum standards for flammability:
  • ASTM E84:  Standard Test Method for Surface Burning Characteristics of Building Materials:  Flame spread 25
  • ASTM D635:   Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position:  Self-extinguish
  • UL 94 Tests for Flammability of Plastic Materials for Parts in Devices and Appliances:  V-0

Can this material be considered an equivalent to non-combustible material?

​While Fiberglass Reinforced Polymer (FRP) materials have an excellent fire resistance rating under ASTM and UL tests, it is not specifically classified as non-combustible under ASTM E136.

​​​​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
2 Comments

Foam/Water Deluge System with Less Than K5.6?

3/23/2020

4 Comments

 
I have an existing foam/water deluge system covering vessels and sprinklers providing area coverage for pool fires. The sprinklers are smaller than K-5.6. The owner wants us to match the existing sprinklers. 

In your opinion, is this acceptable?

For reference, NFPA 13 (2013) Section 8.3.4:
8.3.4 Sprinklers with K-Factors Less than K-5.6 (80).
8.3.4.1 Sprinklers shall have a minimum nominal K-factor of 5.6 (80) unless otherwise permitted by 8.3.4...
8.3.4.2 For light hazard occupancies not requiring as much water as is discharged by a sprinkler with a nominal K-factor of K-5.6 (80) operating at 7 psi (0.5 bar), sprinklers having a smaller orifice shall be permitted, subject to the following restrictions:
(1) The system shall be hydraulically calculated.
(2) Sprinklers with nominal K-factors of less than K-5.6 (80) shall be installed only in wet pipe sprinkler systems or in
accordance with the limitations of 8.3.4.3 or 8.3.4.4.
(3) A listed strainer shall be provided on the supply side of sprinklers with nominal K-factors of less than K-2.8 (40).
8.3.4.3 Sprinklers with nominal K-factors of less than K-5.6 (80) shall be permitted to be installed in conformance with 11.3.2 for protection against exposure fires.
8.3.4.4 Sprinklers with nominal K-factors of K-4.2 (57) shall be permitted to be installed on dry pipe and preaction systems protecting light hazard occupancies where piping is corrosion resistant or internally galvanized.


NFPA 15 (2017) Section 7.3.3. Flammable and Combustible Liquid Pool Fires
Water spray systems designed to control pool fires resulting from a flammable or combustible liquid spill fire shall be designed to apply a net rate of not less than 0.30 gpm/sqft of protected area.


I think my new design will require nozzles spaced at 100 square feet if the k-factor needs to be smaller than k-5.6 under NFPA 13.

Also, do you know of any non-aspirating nozzles that are listed for foam?

​​​​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
4 Comments

Is it a "Sprinkler" or "Sprinkler Head"?

3/20/2020

10 Comments

 
Well? What do you think?

Is it a "Sprinkler" or a "Sprinkler Head"?

[Editor's note: there's nothing like a nice Friday release of all that pent-up virus frustration, right!? Have a safe & great weekend everyone]

​​​​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
10 Comments

Would Penthouse Elevation Require Standpipes?

3/19/2020

5 Comments

 
Would a mechanical penthouse be considered a “story” in terms of the 30-ft. standpipe threshold?

If the mechanical penthouse is not occupied, does it still apply for the 30-ft limit? Although that would be logical, I can’t the word “occupied” used anywhere except related to high-rise.  I suppose a mechanical penthouse could be considered a mezzanine, I see some commentary that a mezzanine should be no more than 1/3 of the related floor.

The project has three floors where the top classroom floor is 28 feet above fire department access.  But, there’s a mechanical level above that is much higher. It’s accessible, is it a “story” in terms of standpipe?  It would seem logical that this penthouse doesn’t count.  But I’m not 100% sure code backs me up on this.

Of course the thing that bites us, is whether or not the standpipe is manual or automatic – we have fond this to be totally up to the discretion (sometimes whim), of the AHJ.  Sometimes based on good reasoning, sometimes it has causes the unnecessary (IMHO) requirement for a fire pump.

​​​​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
5 Comments

Does Elevator Trigger Fire Sprinklers for Building?

3/18/2020

5 Comments

 
I had thought the presence of the elevator itself does not necessarily require a sprinkler system if the building does not require a sprinkler system.

For example, if a two-story, type II-B, Business (B) Occupancy building is under 23,000 sqft, the IBC does not require a sprinkler system to be installed. Therefore, the hoistway or the EMR would not require sprinklers.

I’ve had elevator designers argue that the presence of hydraulic fluid requires sprinklers.

I disagree, however; hydraulic fluid is typically a Class III-B flammable liquid. In the example above a two stop elevator would have less than 1000 lb (~150 gal) of hydraulic fluid which does not trigger any Hazardous Occupancy as the control area volume limit for closed-use systems is 13,200 gallons.

Is this the correct approach to take? Does the presence of the hydraulic fluid or any other component of an elevator trigger sprinkler requirements for the rest of the building?

​​​​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
5 Comments

Non-Ferrous Hanging Materials for MRI Room?

3/17/2020

7 Comments

 
I have to do a sprinkler design for an MRI room and I need all the hangers and sway brace components to be non-ferrous material.

Where can I finds non-ferrous components for hangers and sway brace?

​​​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
7 Comments

Is Wood Stair Wrapped in Gypsum "Combustible"?

3/16/2020

3 Comments

 
We have a 2-hour fire rated stair enclosure. The stair landings and stairs are built with wood but are covered with drywall and gypcrete. 

Is this considered a combustible stair requiring sprinklers at every landing?

​​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
3 Comments

Remove a Redundant Fire Pump from Service?

3/13/2020

11 Comments

 
My employer owns several properties in with 2 fire pumps that are discharging to the same loop. The pumps were there when we bought the buildings.  In most cases there is one electric and one diesel, but in other cases there are two diesel fire pumps.

The power purveyor is not considered unreliable by any criteria.

Is there anything you can think of that would prohibit me from decommissioning a redundant pump for the purpose of saving on maintenance costs?

Each pump is 2000 gpm and the greatest demand on the loop is less than 3,000 gpm. The pumps are provided in parallel. 

​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
11 Comments

Are Multiple FDCs Allowed on One Building?

3/12/2020

11 Comments

 
Hi there, just reviewing NFPA 13 for the number of Fire Department Connections allowed on any one building.

I see NFPA 13 16.12.5.6 indicates that sign is required if an FDC only serves a portion of the building. Does it state that only one FDC per building is allowed, or can you have multiple FDC's on one building? Thank you.

​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
11 Comments

Design Criteria for Stacked Boat Storage Facility?

3/11/2020

7 Comments

 
We are looking at a boat storage facility in the northeast. The facility is 42-ft high storing fiberglass boats. It's unheated. The owner doesn't want in rack sprinklers, nor does he want a fire pump.

What would be the fire sprinkler design criteria for this type of facility?

​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
7 Comments

Design Guidance for Pipe Expansion Joints?

3/10/2020

6 Comments

 
I'm working on a project with a very extensive horizontal standpipe; it is about 2000 feet long and in a loop, so almost 5,000 linear feet when all said and done.

Where can I find guidance on providing expansion joints?

Due to the system being so long, we're worried about providing some flexibility in the instance of extreme temperature swings (Virginia). Would seismic flexible joints be appropriate?

​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
6 Comments

Chicago Minimum Density/Area Requirement?

3/9/2020

4 Comments

 
Sorry if this is too location-specific, but I have a question I'd like to get other designer/engineer input on. The Chicago Building Code (Section 15-16-600) specifically has their own density/area requirements, with a minimum of 0.10 gpm over 1,500 sqft for NFPA 13 applications.

Does this mean that they do not accept residential sprinklers (most demanding 4 adjacent residential sprinklers)? Do they also not accept the area reductions for quick-response sprinklers?

Based on the requirement in the code they certainly have the ability/right to override NFPA 13, I just haven't seen any other jurisdiction overrule the allowances in NFPA 13 and was curious if this holds up for other installers in the area.

​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
4 Comments

Fire Pumps - Benefits of 1770 RPM vs. 3560 RPM?

3/6/2020

3 Comments

 
A question for the pump experts on the forum; the line of horizontal split-case fire pumps I'm familiar with generally come as 1770 RPM or 3560 RPM.

What is the benefit to using one versus the other? Do contractors generally have a preference? Is cost, sounds, wear-and-tear impacted by the RPM selection? Thanks in advance.

​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
3 Comments

Riser with 3" PRV Upstream of Zone Control?

3/5/2020

14 Comments

 
During a hotel stay in NYC over the weekend I noticed the combination standpipe included a 3" pressure reducing valve just upstream of the 3" zone control assembly.

An indicating valve was not installed on the inlet side of the Cla-Val (model 90G-21 with no pressure gauges). A filler piece between the PRV outlet and the butterfly valve included a pressure gauge which was at 60 psi. The 2-1/2" fire hose valve was standard pressure and the express drain was only 2".

This arrangement is not something I would expect to see in the DC metro area, but is it typical of NYC?

​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
14 Comments

Standpipe/Riser Clearance in Floor Openings?

3/4/2020

1 Comment

 
We have a combination sprinkler/standpipe riser through floor-level landings in a stairwell of our building. There is a project requirement to provide a pipe sleeve and "required clearance per NFPA 13". 

NFPA 13 gives very clear guidance on clearances in Section 9.3 (NFPA 13 2016 Edition), but that doesn't apply to this project as it is not required to be designed for seismic (Seismic Design Category B).

Where can I determine what clearance needs to be between the pipe and the hole in the concrete stairwell floors/ceilings? I'm not seeing any clearance requirement, but I surely could be missing something. Thanks in advance!

​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
1 Comment

Airport Pump to Serve Both Hydrants & Building?

3/3/2020

6 Comments

 
Big picture question here - I am working on an airport project. We have a Passenger Terminal Building and Aircraft Stands adjacent to the building.

I need to provide sprinkler protection with fire hose cabinets in the Passenger Terminal Building (1,000 gpm at 8 bar / 100 psi), AND fire hydrants to resupply the aircraft rescue and firefighting trucks (1,500 gpm at 6 bar / 87 psi).

Do both of these demands need to be considered together to size the fire pump (both flows combined)? 

We are considering one duty pump and one standby pump. Thanks in advance.

​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
6 Comments

How to Address Missing Hydraulic Placard?

3/2/2020

25 Comments

 
NFPA 25 requires a legible Hydraulic Information Sign.

How do I replace a missing Hydraulic Placard (or calculation plate/card) on an existing system? And what if there isn't original design information available?

I'm curious to see how others are addressing this deficiency.

​​​​​​​​Posted anonymously for discussion. Discuss This | Submit Your Question | Subscribe
25 Comments

Thanks to Our Top February 2020 Contributors!

3/2/2020

 
Wanted to say thank you to all of our community contributors for this past month, and especially those top contributors:
1. Sean
2. Mike
3. Dan Wilder
​4. Jon Sullivan
5. Wayne Ammons
6. Pete D.
​7. Franck
8. Jonathan Joseph
9. Dave
​10. Jesse
    Picture
    Why Sponsor?

    ALL-ACCESS

    Picture
    GET ALL OUR TOOLS

    SUBSCRIBE

    Subscribe and learn something new each day:
    I'm Interested In:

    COMMUNITY

    Top ​Jan 2023 Contributors
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    SEE LEADERBOARD

    YOUR POST

    SUBMIT A QUESTION

    PE EXAM

    Get 100 Days of Free Sample Questions right to you!
    SIGN ME UP!

    FILTERS

    All
    A117.1
    ABA
    ADA
    ASCE 7
    ASME A17.1
    ASTM E1354
    Daily Discussion
    Design Documents
    EN 12845
    Explosion Protection & Prevention
    Fire Detection And Alarm Systems
    Fire Dynamics
    Flammable & Combustible LIquids
    FM Global
    Human Behavior
    IBC
    ICC-500
    IFC
    IMC
    IPC
    IRC
    ISO
    Means Of Egress
    NBC
    NFPA 1
    NFPA 10
    NFPA 101
    NFPA 11
    NFPA 110
    NFPA 1142
    NFPA 1221
    NFPA 13
    NFPA 13D
    NFPA 13R
    NFPA 14
    NFPA 15
    NFPA 16
    NFPA 17A
    NFPA 20
    NFPA 2001
    NFPA 214
    NFPA 22
    NFPA 220
    NFPA 24
    NFPA 241
    NFPA 25
    NFPA 291
    NFPA 30
    NFPA 33
    NFPA 400
    NFPA 409
    NFPA 415
    NFPA 495
    NFPA 497
    NFPA 5000
    NFPA 502
    NFPA 54
    NFPA 55
    NFPA 654
    NFPA 68
    NFPA 70
    NFPA 701
    NFPA 72
    NFPA 75
    NFPA 82
    NFPA 855
    NFPA 90A
    NFPA 92
    NFPA 96
    NICET
    OBC
    Passive Building Systems
    PE Prep Guide
    PE Prep Series
    PE Sample Problems
    Poll
    Smoke Management
    Special Hazard Systems
    UFC 3 600 01
    UFC 3-600-01
    UFC 4-021-01
    Updates
    Water Based Fire Suppression
    Weekly Exams


    ARCHIVES

    February 2023
    January 2023
    December 2022
    November 2022
    October 2022
    September 2022
    August 2022
    July 2022
    June 2022
    May 2022
    April 2022
    March 2022
    February 2022
    January 2022
    December 2021
    November 2021
    October 2021
    September 2021
    August 2021
    July 2021
    June 2021
    May 2021
    April 2021
    March 2021
    February 2021
    January 2021
    December 2020
    November 2020
    October 2020
    September 2020
    August 2020
    July 2020
    June 2020
    May 2020
    April 2020
    March 2020
    February 2020
    January 2020
    December 2019
    November 2019
    October 2019
    September 2019
    August 2019
    July 2019
    June 2019
    May 2019
    April 2019
    March 2019
    February 2019
    January 2019
    December 2018
    November 2018
    October 2018
    September 2018
    August 2018
    July 2018
    June 2018
    May 2018
    November 2017
    October 2017
    September 2017
    August 2017
    July 2017
    June 2017
    November 2016
    October 2016
    July 2016
    June 2016


    PE PREP SERIES

    Fire Protection PE Exam Prep
    SEE LEADERBOARD

    RSS Feed

Picture
​Home
Our Cause
The Blog
The Forum
PE Exam Prep
The Toolkit

MeyerFire University
​Pricing
Login
​Support
Contact Us
Picture

MeyerFire.com is a startup community built to help fire protection professionals shine.
Our goal is to improve fire protection practices worldwide. We promote the industry by creating helpful tools and resources, and by bringing together industry professionals to share their expertise.

​MeyerFire, LLC is an International Code Council Preferred Education Provider.

All text, images, and media ​Copyright © 2023 MeyerFire, LLC

We respect your privacy and personal data. See our Privacy Policy and Terms of Service. 
The views, opinions, and information found on this site represent solely the author and do not represent the opinions of any other party, nor does the presented material assume responsibility for its use. Fire protection and life safety systems constitute a critical component for public health and safety and you should consult with a licensed professional for proper design and code adherence.

Discussions are solely for the purpose of peer review and the exchange of ideas. All comments are reviewed. Comments which do not contribute, are not relevant, are spam, or are disrespectful in nature may be removed. Information presented and opinions expressed should not be relied upon as a replacement for consulting services. Some (not all) outbound links on this website, such as Amazon links, are affiliate-based where we receive a small commission for orders placed elsewhere.

  • Blog
  • Forum
  • THE TOOLKIT
    • SUBMIT AN IDEA
    • BACKFLOW DATABASE*
    • CLEAN AGENT ESTIMATOR*
    • CLOUD CEILING CALCULATOR
    • DOMESTIC DEMAND*
    • FIRE FLOW CALCULATOR*
    • FIRE PUMP ANALYZER*
    • FIRE PUMP DATABASE*
    • FRICTION LOSS CALCULATOR
    • HANGER SPACER*
    • IBC TRANSLATOR*
    • K-FACTOR SELECTOR*
    • NFPA 13 EDITION TRANSLATOR ('19 ONLY)
    • NFPA 13 EDITION TRANSLATOR ('99-'22)*
    • LIQUIDS ANALYZER*
    • OBSTRUCTION CALCULATOR
    • OBSTRUCTIONS AGAINST WALL*
    • PLUMBING FIXTURE COUNTS
    • QUICK RESPONSE AREA REDUCTION
    • REMOTE AREA ANALYZER*
    • SPRINKLER DATABASE*
    • SPRINKLER FLOW*
    • SYSTEM ESTIMATOR*
    • TEST & DRAIN CALCULATOR
    • THRUST BLOCK CALCULATOR
    • TRAPEZE CALCULATOR
    • UNIT CONVERTER
    • VOLUME & COMPRESSOR CALCULATOR
    • WATER STORAGE*
    • WATER SUPPLY (US)
    • WATER SUPPLY (METRIC)
  • UNIVERSITY
    • About
    • Catalog
    • CONTENT LIBRARY
  • PE Exam
    • PE Forum & Errata
    • PE Store
    • PE Tools
    • PE Prep Series
    • PE 100-Day Marathon
  • LOGIN
  • PRICING
    • SOFTWARE & TRAINING
    • STORE
  • THE CAUSE
    • ABOUT US
    • BECOME AN INSTRUCTOR
    • HELP/SUPPORT