How Will You Address AI Made Hydraulic Calcs?

10/12/2026

9 Comments

 
As more and more uses of AI builds occur - what are your thoughts on non-traditional or custom built hydraulic calculations?

It's possible that anyone today, even without AI, could do basic tree or loop systems using Excel or even manual calculations, though it's slower and more painful to create NFPA 13 forms and charts, and basic hydraulic calc programs pay for themselves - hence why we all use them.

But as we go down the road with AI, what happens when someone has ChatGPT create the calcs? Or create a program that does its own calcs?

If I'm an FPE EOR, I don't have the time to QC and validate individual programs and each supporting calculation to make sure it's right. I'm not an AHJ, but I would feel similarly to an AHJ. It's purely my opinion (worth nothing), but there's some inherent trust in the legacy calc programs that, as a reviewer, I'm not double-checking the calculation methods or QC'ing the program, but instead focusing my effort on making sure the inputs are appropriate.

What are your thoughts/plans on addressing it when something rogue comes across your desk? 

Or has it already happened, and how did you handle it?

I know of engineers that specified digitally-created submittals in the 2000s and 2010s, when CAD replaced hand-drawings. Is that something you see getting specified?

Lots to untangle here but curious of your perspective from whatever role you have. Thanks.

​Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
9 Comments
Dan Wilder
10/12/2026 06:56:34 am

NFPA just says "Computer Program" or "Computer-generated", it does not state any listing or approval requirements (for hydraulics, water delivery is still the outlier).

Isn't the validation to be done on the resulting calculation forms and that they match the NFPA requirements for the adopted year, the submitted plans, pipe types, fitting types, valve losses, C-Factors, elevations, distances, water supply...etc.? What difference does the program making the calculations have on that as I can make a very convincing excel report that mimics any of the currently on market hydraulics programs (probably with that same AI).

It's not if, but when...and the experience needed for those human reviews will be invaluable...until another AI check program is brought in for validation, then it's just two systems talking to each other likely with some QR code.

Reply
Glenn Berger
10/12/2026 08:16:03 am

I am unsure if an AI generated drawing or calculations have come across my desk. I still review submittals as required and comment as necessary.

Reply
Anthony
10/12/2026 08:48:57 am

"If I'm an FPE EOR, I don't have the time to QC and validate individual programs and each supporting calculation to make sure it's right."

An EOR is not supposed to validate programs you're supposed to review the calcs. At bare minimum you're supposed to validate main and UG pipe sizing on every job. This is the job get calcs review calcs.

"What are your thoughts/plans on addressing it when something rogue comes across your desk?"

Nothing I expect calculations to come as prescribed in NFPA 13. I think most sprinkler folks can eyeball a poor/good calcs and know if you need to dig in further. If they're not in the form NFPA requires I reject them. Outside of a few big firms most of your work has a locality to it you learn the players and who can and cant do quality work.

I guess I'm missing the problem statement here.

I'd be more worried in a LLM reviewing calcs than making them. That would be an ethical breach at this time. I have near zero trust in the silicon gods to do anything with repeatable correctness. Again at this time. They MAY get good but today we're not there.

Reply
Ricardo Gonzales Jr
10/12/2026 08:54:07 am

As an EoR you need to validate the information. You should either have an abbreviated version on your laptop or know how to quickly hand calc a few of the numbers. As a former AHJ and EoR, I do quick hand calcs to verify the numbers from the start and spot work backwards (not every sprinkler or connection) to the source.

Since there are sprinkler design software that are qualified, it wouldn't be hard for the AI, with some learning, to duplicate the process and give reasonable results. Again, the above paragraph reigns.

Reply
Wes
10/12/2026 08:57:33 am

I agree and I think this is probably where things will head.

A reviewer can't be a validator for the original creation software, but we can use our own software (and AI in the future) to replicate the calcs.

I guess it's not that different from a scientific method result - if you can't replicate it, is it valid to begin with? Or if it can't be replicated, where's the difference/error?

Reply
Jack G
10/12/2026 10:02:38 am

I think its the EOR s responsibility to do a " check calc" with his/her own software as opposed to just reviewing the inputs.
This will sniff out AI false attempts. So many things could be altered , formulas,, etc,, internally that a review may not find.
EOR gets the " big bucks " ( joke)
I ve always done a check calc. Doesn't take that long.

Reply
Jack G
10/12/2026 10:07:34 am

Most reputable Fire protection hydraulic software has tree,loop, grid software to build the model submitted.
Hey, I still remember doing hydraulics with a slide rule. Pickett.

Reply
Dave L.
10/12/2026 10:51:08 am

Acting as EOR reviewing submittals for the owner/architect, my specs say calculations shall be performed on a computer utilizing an approved fire protection hydraulics program. With A1, I may need to begin clarifying what "approved" means. I also accept Excel, but I can't remember the last time someone has submitted that. Regardless of what program is utilized, I do scrutinize the calcs and look for different things, depending on if it is a standalone program with manual entry, or say, Autosprink. I might have a trainee re-run an entire calc, or spot-check certain sections. I always check water supply, elevations, flex drop length, etc. for unintentional (or intentional) deviation. Especially if there isn't much of a safety factor. In my case, I am not (yet) evaluating individual programs, but I evaluate the calcs on various factors, including my trust and familiarity with the submitting contractor.

Reply
Streeter
10/19/2026 11:51:56 am

I make it a point to do a gut check calc for all the projects I review. If things are wildly off I will do node to node checks and make sure things are square for friction loss, sizes, etc.

When it comes to AI calcs it will be pretty obvious that it is not from one of the typical hydraulic programs, and if anything for the calculations is AI slop that doesn't match what should be standard friction loss values, elev. loss, or anything else is clearly plain wrong I would be rejecting the whole submittal and push the burden of correcting every mistake back onto them.

Reply



Leave a Reply.

    SUBMIT A QUESTION
    Picture
    Why Sponsor?

    ALL-ACCESS

    Picture
    GET ALL OUR TOOLS

    SUBSCRIBE

    Subscribe and learn something new each day:
    I'm Interested In:

    COMMUNITY

    Top Oct '26 Contributors
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    SEE LEADERBOARD

    YOUR POST

    SUBMIT A QUESTION

    PE EXAM

    Get 100 Days of Free Sample Questions right to you!
    SIGN ME UP!

    FILTERS

    All
    A1171
    ABA
    ADA
    ASCE 7
    ASME A17.1
    ASTM E1354
    Blog Thread
    Daily Discussion
    Design-documents
    EN 12259-1
    EN 12845
    Explosion Protection
    Explosion-protection-prevention
    Fire Detection And Alarm Systems
    Fire Dynamics
    Flammable And Combustible Liquids
    Flammable-combustible-liquids
    FM Global
    Human-behavior
    IBC
    ICC 500
    IEBC
    IFC
    IMC
    IPC
    IRC
    ISO
    Means Of Egress
    NBC
    NFPA 1
    NFPA 10
    NFPA 101
    NFPA 11
    NFPA 110
    NFPA 1142
    NFPA 1221
    NFPA 13
    NFPA 13D
    NFPA 13R
    NFPA 14
    NFPA 15
    NFPA 16
    NFPA 17A
    NFPA 20
    NFPA 2001
    NFPA 214
    NFPA 22
    NFPA 220
    NFPA 221
    NFPA 24
    NFPA 241
    NFPA 25
    NFPA 291
    NFPA 30
    NFPA 307
    NFPA 30B
    NFPA 31
    NFPA 33
    NFPA 37
    NFPA 400
    NFPA 409
    Nfpa-415
    Nfpa-45
    Nfpa-495
    NFPA 497
    NFPA 5000
    NFPA 502
    NFPA 54
    NFPA 55
    NFPA 654
    NFPA 68
    NFPA 70
    NFPA 701
    NFPA 72
    NFPA 75
    NFPA 770
    NFPA 82
    NFPA 850
    NFPA 855
    NFPA 88A
    NFPA 90A
    NFPA 92
    NFPA 96
    NICET
    OBC
    OSHA
    Passive Building Systems
    PE Prep Guide
    PE Prep Series
    PE Sample Problems
    Poll
    Smoke Management
    Special Hazard Systems
    UFC 3-600-01
    UFC 3-601-02
    UFC 4-021-01
    UFC 4-211-01
    UPC
    Updates
    Water Based Fire Suppression
    Weekly Exams


    ARCHIVES

    November 2026
    October 2026
    September 2026
    August 2026
    July 2026
    June 2026
    May 2026
    April 2026
    March 2026
    February 2026
    January 2026
    December 2025
    November 2025
    October 2025
    September 2025
    August 2025
    July 2025
    June 2025
    May 2025
    April 2025
    March 2025
    February 2025
    January 2025
    December 2024
    November 2024
    October 2024
    September 2024
    August 2024
    July 2024
    June 2024
    May 2024
    April 2024
    March 2024
    February 2024
    January 2024
    December 2023
    November 2023
    October 2023
    September 2023
    August 2023
    July 2023
    June 2023
    May 2023
    April 2023
    March 2023
    February 2023
    January 2023
    December 2022
    November 2022
    October 2022
    September 2022
    August 2022
    July 2022
    June 2022
    May 2022
    April 2022
    March 2022
    February 2022
    January 2022
    December 2021
    November 2021
    October 2021
    September 2021
    August 2021
    July 2021
    June 2021
    May 2021
    April 2021
    March 2021
    February 2021
    January 2021
    December 2020
    November 2020
    October 2020
    September 2020
    August 2020
    July 2020
    June 2020
    May 2020
    April 2020
    March 2020
    February 2020
    January 2020
    December 2019
    November 2019
    October 2019
    September 2019
    August 2019
    July 2019
    June 2019
    May 2019
    April 2019
    March 2019
    February 2019
    January 2019
    December 2018
    November 2018
    October 2018
    September 2018
    August 2018
    July 2018
    June 2018
    May 2018
    November 2017
    October 2017
    September 2017
    August 2017
    July 2017
    June 2017
    November 2016
    October 2016
    July 2016
    June 2016


    PE PREP SERIES

    SEE LEADERBOARD

    SEARCH THE FORUM

    RSS Feed

Picture
​Home
Our Cause
The Blog
The Forum
PE Exam Prep
The Toolkit

MeyerFire University
​Pricing
Login
​Support
Contact Us
Picture

MeyerFire.com is a startup community built to help fire protection professionals shine.
Our goal is to improve fire protection practices worldwide. We promote the industry by creating helpful tools and resources, and by bringing together industry professionals to share their expertise.

​MeyerFire, LLC is a NICET Recognized Training Provider and International Code Council Preferred Education Provider.

All text, images, and media ​Copyright © 2016-2025 MeyerFire, LLC

We respect your privacy and personal data. See our Privacy Policy and Terms of Service. 
The views, opinions, and information found on this site represent solely the author and do not represent the opinions of any other party, nor does the presented material assume responsibility for its use. Fire protection and life safety systems constitute a critical component for public health and safety and you should consult with a licensed professional for proper design and code adherence.

Discussions are solely for the purpose of peer review and the exchange of ideas. All comments are reviewed. Comments which do not contribute, are not relevant, are spam, or are disrespectful in nature may be removed. Information presented and opinions expressed should not be relied upon as a replacement for consulting services. Some (not all) outbound links on this website, such as Amazon links, are affiliate-based where we receive a small commission for orders placed elsewhere.

  • Blog
  • Forum
  • TOOLKIT
    • ALL TOOLS
    • BUY THE TOOLKIT
  • UNIVERSITY
    • ALL COURSES
    • JOIN THE UNIVERSITY
  • PE Exam
    • PE Forum & Errata
    • PE Store
    • PE Tools
    • PE PREP SERIES
    • PE Old Questions
  • STUDENTS
    • LAND JOB/INTERNSHIPS
    • STUDENT CONNECTOR
  • LOGIN
    • TOOLKIT-ONLY LOGIN
    • UNIVERSITY LOGIN
  • STORE
  • OUR CAUSE
    • ABOUT MEYERFIRE
    • JOB OPENINGS
    • BECOME AN INSTRUCTOR
    • HELP/SUPPORT