I have a 10-story condo building with 70 units. Each floor has 7 units, and the unit doors open to an open-atmosphere walkway with two exit stairwells at each end.
Do each unit door that swings into the unit need self-closing hinges? Thanks in advance for your help or guidance with this. Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
7 Comments
Pete H
12/22/2025 06:12:53 am
Is the open-atmosphere walkway covered with partial openings, or is it just exterior?
Reply
Pete H
12/22/2025 09:05:21 am
With the overhang connecting it, I'm inclined to agree with D. Peoples based on townhouses with shared interior walkways are required to have self-closing doors between them and the shared spaces (as well as any interior garages). Yeah, self-closing likely required.
D.Peoples
12/22/2025 08:10:42 am
Yes, according to the International Fire Code (IFC), apartment buildings are required to have self-closing doors during a fire. This requirement is part of the fire safety measures to prevent the rapid spread of fire and smoke within the building. Self-closing doors ensure that the doors automatically return to a closed position after being opened, which is crucial during a fire emergency.
Reply
Nimal Tissa Wijetunga
12/24/2025 06:33:10 pm
Yes. Self closing mechanism required in each apartment unit.
Reply
Todd E Wyatt
12/22/2025 08:15:42 am
Yes, “walls separating dwelling units … shall be constructed as FIRE PARTITIONS“ so the doors into the dwelling units from the open-atmosphere walkway shall be Fire Doors which require self-closing hardware.
Reply
Jack G
12/22/2025 03:56:14 pm
Doors, frames and hardware are required for an egress corridor, and must be self closing and positive latching, (with exception for Healthcare and patient rooms)
Reply