Use NFPA 13D for 2 Apartments Above a Garage?

1/31/2025

5 Comments

 
I have a project with two existing 900 sqft apartments above a non-sprinklered marine repair garage. Only the apartments are required to be sprinklered.

Can I sprinkler the two apartments per NFPA 13D, or do I have to do per NFPA 13R?

I know the definition of dwellings says no more than two dwelling units in 13D. Thank you.


Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
5 Comments

Feed Upper Level with Fire Pump, Lower Without?

1/30/2025

11 Comments

 
Is it okay to design a fire protection system for a building using street pressure for the lower garage dry-pipe system, and using a fire pump for the upper floors when required?

If so, does NFPA 13 have a diagram for this?

Also, how is the system piped to avoid starving the street pressure system when the fire pump engages?


Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
11 Comments

Is Automatic Drain Required for Remote FDC?

1/29/2025

7 Comments

 
In an area subject to freezing, we have a remote FDC that supplies a riser room at the same level. The feed is through underground pipe.

Is the base of the FDC required to have an automatic drain similar to what's at the base of dry barrel fire hydrants?

If not, how are these FDC's typically drained after use?


Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
7 Comments

Pipe to Sprinkler in Elevator Pit Run Along Wall?

1/28/2025

7 Comments

 
We have a two floor building with a hydraulic elevator that is required to have sprinkler protection. Getting to the sprinkler in the pit from first floor is not possible.

My question is, can we feed the sprinkler in the pit from the second floor?

Just pick a corner and pipe along the wall?

The elevator inspector is telling us that our pipe can not run along the wall in the hoistway. How true is this?

Is there circumstances where pipe can run up or down the hoistway, per code?

​Thanks in advance.


Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
7 Comments

How to Address Control Areas in Old Buildings?

1/27/2025

8 Comments

 
We are a large metropolitan area with multiple universities that have been operating for decades with high levels of hazardous materials. They want to have separated control areas, but their building construction does not meet current requirements.

On one side we can only enforce the code that these were built to, which was BOCA or even no building code at the time, but on the other hand, there is a reason why control areas came about in the first place.

As they cannot easily upgrade the structure to meet 2-hr requirements, I am planning on just using equivalent level of safety through sprinkler protection and other factors, but was wondering if anyone had experience doing enforcement like this?

Is NFPA 45 enforceable here?


Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
8 Comments

Two or three vents required for diesel fuel tank?

1/24/2025

6 Comments

 
We have a 119-gallon double-wall fuel tank for our diesel fire pump.

Our tank rep believes we only need (2) vents total: (1)
an emergency vent for the interstitial space and (1) a combined normal/emergency vent for the primary tank.

We have received pushback that we need (3) vents: (1) normal for the primary tank, (1) emergency for the primary tank, and (1) emergency for the interstitial space.

We are having difficulties finding any requirements either allowing or not the combination of the emergency and normal vent lines of the primary tank (NFPA, building code, or UL 142).

Do any of you know if the combination of these vents is typically allowed?

What do you typically see for the venting of a diesel fire pump fuel tank?

​Note, this job does fall under 2022 California Building Code, but I am still interested in what is common even outside of California.


Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
6 Comments

Separate In-Rack & Overhead in Same Calc?

1/23/2025

11 Comments

 
If I have an in-rack system that needs to be calculated with the ceiling system, does the ceiling system need to be positioned above the most demanding racking?

This might result in neither individual component area used being the most demanding of their type.

Or do I calculate the most demanding rack along with the most demanding ceiling?

I drew a quick-and-dirty sketch of a warehouse with the most demanding rack in red, the most demanding ceiling area in green, and the water source in blue.

Picture
If the two areas are not lined up, this goes against the assumption that only one fire is happening in the building at a time. I'm thinking that the two need to be averaged over each other to come up with the most demanding single area, even if the most demanding ceiling or rack are not involved.

​Thanks in advance for your input.


Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
11 Comments

Forward Flow: 2½" Necessary for Each 250 gpm?

1/22/2025

16 Comments

 
In reviewing the top articles from 2024, I re-read #11 regarding forward flow. As an AHJ, this is something we have been focusing on for the last four years and have uncovered multiple water supply issues.

My question is related to NFPA 13 and the 2-1/2” hose valve that is required for every 250 gpm (950 L/min) of system demand. From the fire suppression side, we usually generalize that a 2-1/2” hose valve can only flow 250 gpm.

However, in our forward flow testing and research, we have found that a 2-1/2” hose valve off a main riser can actually flow almost 600 gpm.

So my question to the forum technical design experts is, if we are getting an adequate gpm flow for system demand from the pitot reading, do we really need to flow a hose valve for every 250gpm of system demand?

​In other words, if system demand is 450 gpm and we are getting that from a single 2-1/2” hose valve, is that accurate and acceptable?


Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
16 Comments

NFPA 101 (1-hr) or NFPA 90A (2-hr) in 4-Story Shaft?

1/21/2025

11 Comments

 
NFPA references are based on current editions. While NFPA 101, Section 30.3.1.1.4 (New Apartments) allows vertical penetrations to be protected with a 1-hour rating when sprinklered, NFPA 101, Section 30.5.2 requires HVAC equipment to comply with NFPA 90A.

According to NFPA 90A, Sections 9.1.3 and 6.8.3, a higher level of protection is required for shafts that penetrate more than four floors (2-hr fire rated and fire dampers).

Does the exception provided in NFPA 101 permit reducing the required fire rating to 1-hour for duct shafts, or does NFPA 90A take precedence?

I'm curious to hear different perspectives on this.

I can understand both sides of the issue but find it challenging to justify allowing a 1-hour fire rating for a vertical exit within a New Apartment while requiring a 2-hour fire rating for the duct shafts.


Thanks in advance.
​
Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
11 Comments

What Happened to Hydrants in Pacific Palisades?

1/20/2025

5 Comments

 
Keeping politics out of it, what most likely happened to the fire hydrants in Pacific Palisades, California?

Or looking at both possibilities, what likely happened if all water reservoirs were full and what likely happened if the reservoirs were empty or under repair?

I presume 40 or 50 fire pumper trucks over-taxed a perfectly functioning water system to the point where supply tanks could not be replenished fast enough.

Additionally is a California water reservoir a body of treated water that fills the underground piping system & storage tanks? Or, is a reservoir a body of water (near by) that is waiting to be treated, and then enter the distribution piping?

Looking for a better understanding from those that might be more informed and knowledgeable on the subject here. Thanks.

Moderator's note: Major cultural events have a tendency for discourse to go political quickly. This is a technical forum for technical discussion on topics relevant to the fire protection industry, and not a location for political discourse. We welcome and appreciate civil discourse that's informative and helpful. Please refrain from political commentary as it will be removed from this site. Thank you.


Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
5 Comments

Evaluate Water Hammer on Existing System?

1/17/2025

4 Comments

 
I'm working on a project in an existing 7-story building with an existing 500 gpm 70 psi fire pump.

We are installing a new 4-story riser outside the pump room, and a question of water hammer/surge protection has come up. The existing equipment does not indicate any special considerations for this.

Most (not all) zone valve assemblies incorporate pressure relief valves, and all new zones will have them, as well. Hydrant test static was 65psi.

In general, what conditions would prompt you to consider the possibility of water hammer or pressure surge being an issue?

How do you go about evaluating this, if it is a potential issue?

Thanks in advance.

Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
4 Comments

How to Inspect & Service Valve in Roadway Box?

1/16/2025

8 Comments

 
What is an acceptable means to inspect/supervise underground fire line isolation valves in a "roadway box?"

These are non-indicating and unsupervised valves on a fire line. They do not have a lockable lid and may be in a drive or roadway, i.e. subject to traffic. If you recommend a seal, please be descriptive of how that would be practical.

NFPA 13 provides the following applicable guidance: 16.9.3.3.1 Valves on connections to water supplies, sectional control and isolation valves, and other valves in supply pipes to sprinklers and other fixed water-based fire suppression systems shall be supervised by one of the following methods: (4) Valves located within fenced enclosures under the control of the owner, sealed in the open position, and inspected weekly as part of an approved procedure.

Thanks for your help.
​
Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
8 Comments

How Often to Re-Test Loaded Sprinklers?

1/15/2025

10 Comments

 
In NFPA 25-2017 Chapter 5 addresses "Loaded sprinklers." Of course, this has been a "LOADED" question for years and everybody's interruption of what that is whether or not NFPA gives a decent explanation of it.

My question is, we have a customer that we've performed a sprinkler test by removing an X amount of sprinklers and sending it away to a third party lab for testing which samples came back as a pass - but the question has come up asking if sprinklers remain to be loaded the same if not more over the years.

What would be the timeline for re-testing?

Would it follow the 10 year re-test?

Or 5 Year sprinkler testing that NFPA 25 requires for sprinklers in "hazardous" environment areas?

As this plant has over 600 sprinklers and getting up to them and cleaning them every year is not practical, that option is not on the table. See NFPA 25-2017 code for the discussion on it. 

​Thanks for your take.


Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
10 Comments

Methods to Isolate Pipe Through a SCIF?

1/14/2025

7 Comments

 
I am a project manager currently building a SCIF in Northern Virginia. I was told by the landlord that we couldn't use Schedule 80 PVC for di-electric breaks as they have had a PVC break causing millions of dollars of damage prior. We don't like wrapping/grounding the pipe.

Have you run into this?

Do options exist, and what would you recommend to isolate through a SCIF?


Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
7 Comments

When to Calculate Flexible Armovers in Retrofit?

1/13/2025

15 Comments

 
From my AHJ perspective and in regards to flexible drops and tenant improvements, where you typically don't receive hydraulic calcs, how are you then accounting for their equivalent lengths and friction loss?

I know some AHJ's require new calcs whenever these are being used period. I'm interested to see how others handle this. Thank you!


Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
15 Comments

Congratulations to the Top 2024 Contributors!

1/10/2025

0 Comments

 
Thank you all for continuing to make this Forum such a fantastic place to learn, share, and connect. Over the past year, we’ve seen some great discussions, advice, and insights that have helped shape our industry in a positive way. It’s your participation and willingness to help others that sets this community apart!

We’d like to recognize the Top Forum Contributors in 2024 (in alphabetical order):
Picture
Picture
Picture
Picture
Picture
Picture
Picture
Picture
Picture
Picture
Picture

As a special thank you from our team, each of these contributors will receive a commemorative plaque. They will also have a flag next to their name for future leaderboards. 

Thank you once again for being part of this amazing community. ​Keep sharing, keep learning, and here’s to another great year together!
0 Comments

Sprinklers Required Below Mesh Green Ceiling?

1/10/2025

10 Comments

 
I am working on a sprinkler system where the corridor has a wooden ceiling, as shown below. Upright sprinklers protect the space above the ceiling.

I want to know whether the pendent sprinklers below the ceiling are also required?

Is this an open grid ceiling under NFPA 13?

The ceiling has the following characteristics: Bamboo ceiling panels with mesh void and solid wood frame with galvanized black metal rods as hangers for proper support, panels are to have a consistent panel size of 15 cm void between each panel and the wall and 30 cm void between the panels for the greenery to be hung.

Can anyone help me in this case? Thanks in advance.


Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
Picture
10 Comments

Ceiling-Only Design for 30-ft Cold Storage Area?

1/9/2025

7 Comments

 
I am hoping for some help here. I have a cold storage facility that has racks in it. Customer is adamant they do not want in-rack sprinklers. Building is 30-ft tall to the peak, storage is at 25-ft, racks are push back/drive in 29' deep with no longitudinal flue space. They are storing a Class I commodity.

Is there a ceiling-only design that's possible, for a dry system, for this?

Or a direction for me to look into?

It's not a conditioned space, just a big ice box. I would greatly appreciate any help or feed back, thanks.


Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
7 Comments

Best Fire Sprinkler Temperature for Boiler Room?

1/8/2025

7 Comments

 
Anyone know what temperature the sprinkler should be for a school's boiler room?

Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
7 Comments

Tiny Dry Extra Hazard System Need 2 Insp. Tests?

1/7/2025

3 Comments

 
We have a small dry system of 196 total gallons installed in a small feed/grain storage warehouse at a Tractor Supply store. The dry valve is very close to the unheated storage area. They are using racks with commodity stored up to 15 ft high. This system is well under the 500 gallons for required water delivery time.

Is the Extra Hazard Inspectors test still required with two lines, two outlets on each line, or is a typical Inspectors test for Ordinary Hazard acceptable?

I assume the Extra hazard arrangement is still required, but wanted some clarification. NFPA 13 Figure A.7.2.3.7 shows the manifold from four sprinklers and two branch lines.


Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
3 Comments

Do I Even Consider More-Recent Code Editions?

1/6/2025

15 Comments

 
My area's adopted building code references NFPA 13, the 2016 Edition.

Should I even consider looking into the later versions of NFPA 13 (2019-present)?

​If there are major differences, how do we reconcile following only 2016 since the building code references it even though it may be outdated now?

​
Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
15 Comments

Is the Fire Pump House Req'd to Be Sprinklered?

1/3/2025

8 Comments

 
Is it required by IBC or NFPA 13 to have a detached fire pump room or shelter to be protected by the sprinkler system as long as the fire pump serves the sprinkler protected building?

Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
8 Comments

Thank You to Top December 2024 Contributors!

1/2/2025

 
Thank you for keeping discussions strong during the holidays. Special Shout out to our Top Contributors to the Forum for December 2024! 
Picture
Picture
Picture
Picture
Picture
Picture
Picture
Picture
Picture
Picture

Are Townhouse Complexes Group R-2 or R-3?

1/2/2025

12 Comments

 
Are townhouse complexes (3 or more side by side and separated by fire barrier) considered R-2 or R-3?

Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
12 Comments

Why Use Fire Engine for Bldg FDC that has Pump?

1/1/2025

7 Comments

 
Operationally, why would a fire department with a 1,500 gpm pump on a fire engine connect to a building FDC that has a 1,750 gpm pump?

Sent in anonymously for discussion. Click Title to View | Submit Your Question | Subscribe
7 Comments
    SUBMIT A QUESTION
    Picture
    Why Sponsor?

    ALL-ACCESS

    Picture
    GET ALL OUR TOOLS

    SUBSCRIBE

    Subscribe and learn something new each day:
    I'm Interested In:

    COMMUNITY

    Top Dec '25 Contributors
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    Picture
    SEE LEADERBOARD

    YOUR POST

    SUBMIT A QUESTION

    PE EXAM

    Get 100 Days of Free Sample Questions right to you!
    SIGN ME UP!

    FILTERS

    All
    A1171
    ABA
    ADA
    ASCE 7
    ASME A17.1
    ASTM E1354
    Blog Thread
    Daily Discussion
    Design-documents
    EN 12259-1
    EN 12845
    Explosion Protection
    Explosion-protection-prevention
    Fire Detection And Alarm Systems
    Fire Dynamics
    Flammable And Combustible Liquids
    Flammable-combustible-liquids
    FM Global
    Human-behavior
    IBC
    ICC 500
    IEBC
    IFC
    IMC
    IPC
    IRC
    ISO
    Means Of Egress
    NBC
    NFPA 1
    NFPA 10
    NFPA 101
    NFPA 11
    NFPA 110
    NFPA 1142
    NFPA 1221
    NFPA 13
    NFPA 13D
    NFPA 13R
    NFPA 14
    NFPA 15
    NFPA 16
    NFPA 17A
    NFPA 20
    NFPA 2001
    NFPA 214
    NFPA 22
    NFPA 220
    NFPA 24
    NFPA 241
    NFPA 25
    NFPA 291
    NFPA 30
    NFPA 307
    NFPA 30B
    NFPA 31
    NFPA 33
    NFPA 37
    NFPA 400
    Nfpa-409
    Nfpa-415
    Nfpa-45
    Nfpa-495
    NFPA 497
    NFPA 5000
    NFPA 502
    NFPA 54
    NFPA 55
    NFPA 654
    NFPA 68
    NFPA 70
    NFPA 701
    NFPA 72
    NFPA 75
    NFPA 770
    NFPA 82
    NFPA 850
    NFPA 855
    NFPA 90A
    NFPA 92
    NFPA 96
    NICET
    OBC
    OSHA
    Passive Building Systems
    PE Prep Guide
    PE Prep Series
    PE Sample Problems
    Poll
    Smoke Management
    Special Hazard Systems
    UFC 3-600-01
    UFC 4-021-01
    UFC 4-211-01
    UPC
    Updates
    Water Based Fire Suppression
    Weekly Exams


    ARCHIVES

    January 2026
    December 2025
    November 2025
    October 2025
    September 2025
    August 2025
    July 2025
    June 2025
    May 2025
    April 2025
    March 2025
    February 2025
    January 2025
    December 2024
    November 2024
    October 2024
    September 2024
    August 2024
    July 2024
    June 2024
    May 2024
    April 2024
    March 2024
    February 2024
    January 2024
    December 2023
    November 2023
    October 2023
    September 2023
    August 2023
    July 2023
    June 2023
    May 2023
    April 2023
    March 2023
    February 2023
    January 2023
    December 2022
    November 2022
    October 2022
    September 2022
    August 2022
    July 2022
    June 2022
    May 2022
    April 2022
    March 2022
    February 2022
    January 2022
    December 2021
    November 2021
    October 2021
    September 2021
    August 2021
    July 2021
    June 2021
    May 2021
    April 2021
    March 2021
    February 2021
    January 2021
    December 2020
    November 2020
    October 2020
    September 2020
    August 2020
    July 2020
    June 2020
    May 2020
    April 2020
    March 2020
    February 2020
    January 2020
    December 2019
    November 2019
    October 2019
    September 2019
    August 2019
    July 2019
    June 2019
    May 2019
    April 2019
    March 2019
    February 2019
    January 2019
    December 2018
    November 2018
    October 2018
    September 2018
    August 2018
    July 2018
    June 2018
    May 2018
    November 2017
    October 2017
    September 2017
    August 2017
    July 2017
    June 2017
    November 2016
    October 2016
    July 2016
    June 2016


    PE PREP SERIES

    SEE LEADERBOARD

    SEARCH THE FORUM

    RSS Feed

Picture
​Home
Our Cause
The Blog
The Forum
PE Exam Prep
The Toolkit

MeyerFire University
​Pricing
Login
​Support
Contact Us
Picture

MeyerFire.com is a startup community built to help fire protection professionals shine.
Our goal is to improve fire protection practices worldwide. We promote the industry by creating helpful tools and resources, and by bringing together industry professionals to share their expertise.

​MeyerFire, LLC is a NICET Recognized Training Provider and International Code Council Preferred Education Provider.

All text, images, and media ​Copyright © 2016-2025 MeyerFire, LLC

We respect your privacy and personal data. See our Privacy Policy and Terms of Service. 
The views, opinions, and information found on this site represent solely the author and do not represent the opinions of any other party, nor does the presented material assume responsibility for its use. Fire protection and life safety systems constitute a critical component for public health and safety and you should consult with a licensed professional for proper design and code adherence.

Discussions are solely for the purpose of peer review and the exchange of ideas. All comments are reviewed. Comments which do not contribute, are not relevant, are spam, or are disrespectful in nature may be removed. Information presented and opinions expressed should not be relied upon as a replacement for consulting services. Some (not all) outbound links on this website, such as Amazon links, are affiliate-based where we receive a small commission for orders placed elsewhere.

  • Blog
  • Forum
  • TOOLKIT
    • ALL TOOLS
    • BUY THE TOOLKIT
  • UNIVERSITY
    • ALL COURSES
    • JOIN THE UNIVERSITY
  • PE Exam
    • PE Forum & Errata
    • PE Store
    • PE Tools
    • PE PREP SERIES
    • PE Old Questions
  • LOGIN
    • TOOLKIT-ONLY LOGIN
    • UNIVERSITY LOGIN
  • STORE
  • OUR CAUSE
    • ABOUT MEYERFIRE
    • JOB OPENINGS
    • BECOME AN INSTRUCTOR
    • HELP/SUPPORT